about-banner-image

ERAM GENSET POWERED BY VOLVO EICHER ENGINE DG SET RANGE(30KVA TO 160KVA)

DG Set with Perkins Engine


HIGHLIGHT :

• Highest efficiency in its class.
• Voltage Regulation 1- 1% (optional 1- 0.5%).
• Suitable for outdoor 8 harsh weather condition installations
• Easy access to accessories with secure serviceability
• Integral MCP Panel
• Integral Fuel tank with 3 Way fuel Indication
• Powder coated with Nine Tank pre-treatment for durability
• Silencer with Bird protection cover and Tail pipe


SALIENT FEATURES

  • → Advanced Technology and Best Metallurgy
  • → Most fuel efficient engine in its class
  • → Longer duration oil change period
  • → Lubrication oil cooler and bypass filter inbuilt
  • → Lower Maintenance Cost
  • → Piston cooling nozzle
  • → Extremely Low Vibration
  • → In Line Fuel Pump
  • → Starter Motor with Thermal Cut off
  • → Easy Serviceability and spares availability
  • → Best block loading- Suitable for AMF Function


STANDARD SCOPE:

Lighting Inside the Acoustic Enclosure Included
Lighting Inside the Acoustic Enclosure Included
Fuel Tank & Fuel Piping Inbuild (Removable Type with Lock & Key Arrangement)
First fill of Lube Oil & Coolant Included
Power Cable Included within Acoustic Enclosure (Between Alternator & DG Pan
Silencer with Tail Pipe Included
Fuel Level Gauge & Sensor Included
Emergency Stop Button Included

OPTIONALS:

  • → Transportation & Transit Insurance
  • → Unloading & Shifting of DG Set at Site
  • → Civil Foundation at Site
  • → Power & Control Cabling outside Acoustic Enclosure
  • → Earthing of Equipment (DG Set & Panel) at Site
  • → Exhaust Pipe Extension
  • → Any kind of Statutory Approval
TECHNICAL SPECIFICATIONS
Genset Rating KVA 30 40 50 62.5 75 82.5 100 125 140 160
Power Factor PF 0.8
Genset Raring kWe 24 32 40 50 60 66.00 80 100. 00 112 128
Engine Rated Power BHP 38 52 65 80 105 105 128 156 201 201
Engine Make EICHER (VECV)
Engine Model EE483TCI EE483TCI EE483TCI EE483TCI EE683TCI EE683TCI EE694TC1 EE694TCI EE694TC1 EE694TC1
No. of Cylinders No. 4 4 4 4 6 6 6 6 6 6
Nature of Aspiration TCI TO TO TO TCI TCI TCI TO TO TO
Displacement Liters 3.3 3.3 3.3 3.3 4.9 4.9 5.7 5.7 5.7 5.7
Compression Ratio 17:01 17:01 17:01 17:01 17:01 17:01 17.5:0 1 17.5:0 1 17.5:0 1 17.5:0 1
Bore X Stroke MM 100 x 105 100 x 105 100 x 105 100 x 105 100 x 105 100 x 105 100 X 120 100 X 120 100 X 120 100 X 120
Electric System Volt 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V DC
Battery AH 88 88 88 88 120 120 120 120 120 120
Lube Oil Consumption % F Cons 1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Ltbe Oil System Capacity Liters 11 11 11 11 14 14 23 8 23 8 23 8 23 8
Service Interval Fburs/Mo nth 500 Hours/12 Months 700 Flours/12 Months
Governing Type Mechanical Mechanical/ Electronic 700 Flours/12 Months
Fuel Tank Cap Ltrs 95 95 120 120 180 180 180 180 250 250
Alternator Make (') LER OY SOM ER/ MECC ALTE STAM FORD
Alternator Type BRUSHLESS
No. of Phase 3 Phase/ Phase 3 Phase
Type of Pane STANDARD MANUAL PANEL (OPTIONAL AMFPANEL)
Acoustic Enclosure Size' (Lx1A1) 4-1)rnrn 2500 X 1050 X 1500 2800 X 1050X 1500 3200X 1250 X 1500 3750 X 1250X 1500 3800 x 1400 x 1800
Approx DG Set Weight' Kgs 1150 1
1200
1450 1 1450 1700 1 1700 2000 2000 2400 1
2400


Generators